Fuel Pump Relay
NOTE:
Fuel pump relay is also know as PGM-FI relay.
- Remove fuel pump main relay located at left side of cowl. Connect battery voltage to terminal No. 4 and ground to terminal No. 8 of main relay. See Fig 1 .
- Check continuity between relay terminals No. 5 and 7. If continuity exists, go to next step. If continuity does not exist, replace relay.
- Connect battery positive to relay terminal No. 6 and battery negative to terminal No. 2. Check continuity between relay terminals No. 1 and 3. If continuity exists, go to next step. If continuity does not exist, replace relay.
- Connect battery positive to relay terminal No. 3 and battery negative to terminal No. 8. Check continuity between relay terminals No. 5 and 7. If continuity exists, relay is okay. If continuity does not exist, replace relay.