Ignition Coil Test (Vigor)
Turn ignition off. Disconnect ignition coil connector. See Fig 1. Using an ohmmeter, check resistance between indicated terminals. See IGNITION COIL RESISTANCE (VIGOR) table. Replace coil if readings are not within specifications.
IGNITION COIL RESISTANCE - VIGOR
| Application | Ohms @ 68°F (20°C) |
|---|---|
| Terminals A & D (Primary) | .3-.5 |
| Terminals B & D | 2000-2300 |
| Terminal A & Secondary Terminal | 10,800-16,200 |