Rectifier Diodes
NOTE:
Use an ohmmeter capable of checking diodes.
- Check for continuity between terminal "B" and terminals P1-P5 and between terminal "E" and terminals P1-P5. See Fig 1. Note ohmmeter reading.
- Reverse leads, and repeat test. Continuity should be present in one direction and not in other. If continuity is not as specified, replace rectifier assembly.