No MIL

  1. Turn ignition on. If oil pressure light is on, go to next step. If light is off, inspect fuse No. 23. If fuse No. 23 is okay, repair open circuit in Yellow wire between fuse and instrument cluster.
  2. If oil pressure light is on, turn ignition off. Connect ECM test harness connector between ECM and ECM connectors. Jumper ECM terminal A13 to body ground. See Fig 1 . Turn ignition on. If MIL is now on, go to next step. If light is off, replace MIL bulb or repair open in Green/Orange wire between ECM terminal A13 and instrument cluster.
  3. Measure voltage individually between ground and ECM terminals A23 and A24. If more than one volt is present on either terminal, repair open in that wire between ECM and ground terminal G101, located at thermostat housing. See Fig 2 . If less than one volt is present on each terminal, replace ECM and retest.
    Fig 1: Connecting ECM Test Harness
    G92A26203Courtesy of AMERICAN HONDA MOTOR CO., INC.
    Fig 2: Identifying Ground Terminal G101
    G92J26202Courtesy of AMERICAN HONDA MOTOR CO., INC.