EVAP Control Canister
Connect vacuum gauge to canister purge air hose located at bottom of canister. Start engine, and increase engine speed to 3500 RPM. Vacuum gauge should indicate 0-4 in. Hg within one minute. If reading is not as specified, replace charcoal canister.