Rectifier Diodes
NOTE:
Use an ohmmeter capable of checking diodes.
- Check for continuity between rectifier assembly terminal "B" and terminals P1-P4, and between terminals "E" and P1-P4. Refer to Fig 1 . Note ohmmeter reading.
- Reverse leads, and repeat test. Continuity should only be present in one direction. If continuity is not as specified, replace rectifier assembly.