LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Acura >> 1997 >> SLX >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> Bench Testing >> Rectifier Diodes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Rectifier Diodes

NOTE: Use an ohmmeter capable of checking diodes.
  1. Check for continuity between rectifier assembly terminal "B" and terminals P1-P4, and between terminals "E" and P1-P4. Refer to Fig 1 . Note ohmmeter reading.
  2. Reverse leads, and repeat test. Continuity should only be present in one direction. If continuity is not as specified, replace rectifier assembly.
Fig 1: Identifying Rectifier Terminals
G95F34954Courtesy of AMERICAN HONDA MOTOR CO., INC.