Bench Testing: Rotor: Integra
Ensure rotor bearings rotate smoothly. Using ohmmeter, check continuity between slip rings and rotor, individually. Check continuity between slip rings and rotor shaft, individually. See Figure . If continuity exists, replace rotor. Check continuity between slip rings. If continuity does not exist, replace rotor.