Pressure Retaining - TCS Control
TCS NO solenoid valve open, TCS NC solenoid valve, inlet valve and outlet valve are all closed, pump motor is on. Front caliper fluid is retained by inlet and outlet valves.
TCS NO solenoid valve open, TCS NC solenoid valve, inlet valve and outlet valve are all closed, pump motor is on. Front caliper fluid is retained by inlet and outlet valves.