HO2S Monitor Code
NOTE:
Once test is started DO NOT turn ignition switch off. When negative battery cable is disconnected, all readiness codes are cleared.
Ensure ambient temperature is 20-95°F (-7-35°C).
- Connect scan tool to DLC.
- Start engine and hold at 3000 RPM with no load (in park or neutral) until radiator fan comes on.
- Let engine idle for 5 seconds.
- Drive vehicle at steady speed between 50 and 62 MPH for about two minutes
- With A/T in "D" position, M/T in 5th gear, decelerate from 62 MPH by completely releasing throttle for 5 seconds.
- Bring vehicle to a stop. Leave engine running at idle speed. If engine is stalls or is shut off during this part of procedure, repeat procedure starting in step 4.
- Readiness code should now be set. Use scan tool to check readiness code.