LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Acura >> 2003 >> 3.2CL Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Performance System Self-Diagnostics >> Drive Cycles >> System Readiness Test Codes >> EVAP Leak Monitor Codes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

EVAP Leak Monitor Codes

NOTE: When negative battery cable is disconnected, all readiness codes are cleared.
NOTE: If engine is stopped between steps  6 and  16 , repeat procedure from step  1 .
  1. Ensure fuel level is between 60 and 90 percent of fuel tank capacity (not full).
  2. Turn ignition switch off.
  3. Let vehicle set for more than 8 hours.
  4. Ensure outside temperature is 20-95°F (-7-35°C).
  5. Connect scan tool to DLC.
  6. Start engine and drive for about 15 minutes.
  7. Maintain vehicle at steady speed between 50 and 70 MPH, without moving accelerator pedal, for about one minute.
  8. Stop vehicle, engine running.
  9. Repeat steps  7 and  8 two more times.
  10. Check for readiness code with scan tool. If readiness code is not complete, go to next step.
  11. When ambient temperature is less than 32°F (0°C), hold engine speed at 3000 RPM with no load (in park or neutral) until radiator fan comes on.
  12. When ambient temperature is more than 86°F (30°C), remove fuel fill cap, then reinstall.
  13. Drive for about 20 minutes on highway.
  14. Maintain vehicle at steady speed between 50 and 70 MPH, without moving accelerator pedal, for about one minute.
  15. Stop vehicle, engine running.
  16. Repeat steps  14 and  15 two more times.
  17. Check for readiness code with scan tool.