Pulser Test
- Reconnect the 6P connector to the window motor.
- Check for voltage between the terminals: There should be battery voltage between the No. 6 (+) and No. 4 (-) terminals when the ignition switch ON (II).
- If there is no battery voltage, check for an open in the wire.
- Check the voltage between terminals:
- Connect an analog voltmeter between the No. 5 (+) and No. 4 (-) terminals, and run the window motor at down or up. The voltmeter needle should move back and forth alternately (a digital voltmeter should show the average voltage between 0-5 V).
- Connect an analog voltmeter between the No. 3 (+) and No. 4 (-) terminals, and run the window motor at down or up. The voltmeter needle should move back and forth alternately (a digital voltmeter should show the average voltage between 0-5 V).
- If the voltmeter does not indicate as specified, replace the window motor.