Transfer Fuel Pump Test
Special Tools Required
Vacuum pump/gauge, 0-30 in.Hg, Snap-on YA4000A or equivalent, commercially available
- Remove the secondary fuel gauge sending unit (see SECONDARY FUEL GAUGE SENDING UNIT REMOVAL/INSTALLATION ).
- Connect the vacuum pump/gauge 0-30 in.Hg to the transfer tube (A).
- Turn the ignition switch ON (II).
- From the INSPECTION MENU of the HDS, select Fuel Pump ON.
- Read the vacuum pump/gauge 0-30 in.Hg. The vacuum should be 4.0 kPa (1.2 in.Hg, 30 mmHg).
- If the vacuum is OK, the transfer fuel pump and transfer tube is OK.
- If the vacuum is out of specification, go to step 6.
- Turn the ignition switch OFF.
- Install the secondary fuel gauge sending unit (see INSTALLATION ).
- Remove the fuel tank unit (see FUEL TANK UNIT REMOVAL AND INSTALLATION ).
- Connect the vacuum pump/gauge 0-30 in.Hg to the fuel tank unit.
- Lower the fuel tank unit (A) into the fuel tank until the pick up screen is submerged in the fuel.
- Connect the fuel tank unit 4P connector.
- Turn the ignition switch ON (II).
- From INSPECTION MENU of the HDS, select Fuel Pump ON.
- Read the vacuum pump/gauge 0-30 in.Hg. The vacuum should be 4.0 kPa (1.2 in.Hg, 30 mmHg).
- If the vacuum is OK, replace the transfer tube, then recheck the fuel vacuum.
- If the vacuum is out of specification, replace the fuel tank unit (see FUEL TANK UNIT REMOVAL AND INSTALLATION ), then recheck the fuel vacuum.