LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Acura >> 2007 >> RL >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Windows >> Power Window Motor Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Power Window Motor Test

Motor Test 

  1. Remove the door panel (see FRONT DOOR PANEL REMOVAL/INSTALLATION ).
  2. Disconnect the 6P connector (A) from the power window motor.
    Fig 1: Identifying Power Window Motor Connector (6P)
    G05497078Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Test the motor in each direction by connecting battery power and ground as shown (see Fig 2). When the motor stops running, disconnect one lead immediately.
    Fig 2: Testing Motor Operation By Connecting Battery Power And Ground As Shown
    G05497079Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. If the motor does not run or fails to run smoothly, replace it.

    Pulser Test 

  5. Measure the voltage between the terminals.

    Common

    There should be battery voltage between the No. 6 (No. 1)* (+) and No. 5 (No. 2)* (-(terminals when the ignition switch is ON (II).

    * : Front passenger's and left rear power window motor

    Driver's power window motor

    Connect an analog voltmeter between the No. 2 (PLSA) (+) and No. 5 (SGND) (-) terminals, and between No. 3 (PLSB) (+) and No. 5 (SGND) (-) terminals, then run the power window motor down or up. The voltmeter needle should move back and forth alternately (a digital voltmeter should show the average voltage between 0-5 V).

    Front passenger's power window motor/Left rear power window motor

    Connect an analog voltmeter between the No. 5 (PLSA) (+) and No. 2 (SGND) (-) terminals, and between No. 4 (PLSB) (+) and No. 2 (SGND) (-) terminals, then run the power window motor down or up. The voltmeter needle should move back and forth alternately (a digital voltmeter should show the average voltage between 0-5 V).

    Right rear power window motor

    Connect an analog voltmeter between the No. 2 (PLSA) (+) and No. 5 (SGND) (-) terminals, and between No. 3 (PLSB) (+) and No. 5 (SGND) (-) terminals, then run the power window motor down or up. The voltmeter needle should move back and forth alternately (a digital voltmeter should show the average voltage between 0-5 V).

  6. If the voltage is not as specified, do these input tests:
  7. If the input tests are OK, replace the power window motor.
  8. Reset the power window control unit (see RESETTING THE POWER WINDOW CONTROL UNIT  ).