Shift Lock Solenoid Test
- Connect the HDS to DLC.
- Make sure the HDS communicates with the PCM. If it does not, go to the DLC circuit troubleshooting (see DLC CIRCUIT TROUBLESHOOTING (PART 2) ).
- Select Shift Lock Solenoid Valve Test in the Miscellaneous Test Menu, and check that the shift lock solenoid works with the HDS.
- Perform the shift lock solenoid function test: Check that the shift lever can be moved from P when SOLENOID ON. Move the shift lever back to P, and make sure it locks with SOLENOID OFF.
- Check that the shift lock releases when the shift lock release is pushed, and check that it locks when the shift lock release is released.
- If the shift lock solenoid does not work properly, do the shift lock system circuit troubleshooting (see SHIFT LOCK SYSTEM/REVERSE LOCK SYSTEM CIRCUIT TROUBLESHOOTING ).