Ignition Timing Inspection
- Connect the Honda Diagnostic System (HDS) to the data link connector (DLC) (see step 2 on GENERAL TROUBLESHOOTING INFORMATION ).
- Turn the ignition switch ON (II).
- Make sure the HDS communicates with the vehicle and the engine control module (ECM)/powertrain control module (PCM). If it doesn't, troubleshoot the DLC circuit (see DLC CIRCUIT TROUBLESHOOTING ).
- Check for DTCs. If a DTC is present, diagnose and repair the cause before continuing with this test.
- Start the engine. Hold the engine speed at 3,000 RPM without load (in Neutral) until the radiator fan comes on, then let it idle.
- Check the idle speed (see IDLE SPEED INSPECTION ).
- Jump the SCS line with the HDS.
- Connect the timing light to the service loop (white tape).
- Aim the light toward the pointer (A) on the cam chain case. Check the ignition timing under a no load condition (headlights, blower fan, rear window defogger, and air conditioner are turned off).
Ignition Timing
M/T: 8 °±2 ° BTDC (RED mark (B)) at idle in Neutral
A/T: 8 °±2 ° BTDC (RED mark (B)) at idle in Park or Neutral
- If the ignition timing differs from the specification, check the cam timing. If the cam timing is OK, update the ECM/PCM if it does not have the latest software (see UPDATING THE ECM/PCM ), or substitute a known- good ECM/PCM (see SUBSTITUTING THE ECM/PCM ), then recheck. If the system work properly, and the ECM/PCM was substituted, replace the original ECM/PCM (see ECM/PCM REPLACEMENT ).
- Disconnect the HDS and the timing light.