VSA cannot be turned OFF
NOTE:
If the TPMS indicator turns ON, the VSA cannot be turned OFF. Troubleshoot TPMS first.
- Turn the ignition switch to LOCK (0).
- Check the VSA OFF switch (see VSA OFF SWITCH TEST/REPLACEMENT
).
Is the VSA OFF switch OK?
YES -Go to step 3.
NO -Replace the VSA OFF switch (see VSA OFF SWITCH TEST/REPLACEMENT ).
- Disconnect the VSA OFF switch 5P connector (except Canada models with ACC) or VSA OFF switch 13P connector (Canada models with ACC).
- Disconnect gauge control module connector B (24P) (see GAUGE CONTROL MODULE REPLACEMENT ).
- Check for continuity between gauge control module connector B (24P) terminals No. 22 and VSA OFF switch 5P connector terminal No. 2 (except Canada models with ACC) or VSA OFF switch 13P connector terminal No. 11 (Canada models with ACC).Fig 1: Checking Continuity Between Gauge Control Module Connector B (24P) Terminals No. 22 And VSA OFF Switch 5P Connector Terminal No. 2
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Fig 2: Checking Continuity Between Gauge Control Module Connector B (24P) Terminals No. 22 And VSA OFF Switch 13P Connector Terminal No. 11Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 6.
NO -Repair an open in the wire between the gauge control module and the VSA OFF switch.
- Check for continuity between VSA OFF switch 5P connector terminal No. 2 (except Canada models with ACC) or VSA OFF switch 13P connector terminal No. 11 (Canada models with ACC) and body ground.Fig 3: Checking Continuity Between VSA OFF Switch 5P Connector Terminal No. 2 And VSA OFF Switch 13P Connector Terminal No. 11 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair a short to body ground in the wire between the gauge control module and the VSA OFF switch.
NO -Go to step 7.
- Check for continuity between VSA OFF switch 5P connector terminal No. 1 (except Canada models with ACC) or VSA OFF switch 13P connector terminal No. 12 (Canada models with ACC) and body ground.Fig 4: Checking Continuity Between VSA OFF Switch 5P Connector Terminal No. 1 And VSA OFF Switch 13P Connector Terminal No. 12 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Substitute a known-good gauge control module, than go to step 1 and recheck. If it is OK, replace the original gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Repair an open in the wire between the VSA OFF switch and body ground (G501).