Body Control Module Inspection
NOTICE:
Before Disconnecting The SRS Unit Connector, Do The 12 Volt Battery Terminal Disconnection Procedure And Wait For At Least 3 Minutes.
Preconditions
NOTE:
This Procedure Can Be Done Before Any Other Inspections Are Completed Because This Test Procedure Includes All Of The Following Inspection Items. However, If This Test Fails, It Will Be Necessary To Continue With Each Inspection Item Individually To Determine Which Item Failed.
- External Circuit Is Normal
Test Procedure
- Preparation
-
- -
SRS Unit Connector A (43P): Disconnected
- -
- Procedure
-
- -
Perform The Inspection According To The Following Table.
- -
(Connected)Body Control Module Connector B (66P) female Terminals
IG Mode
Normal Conditions
Body Control Module Output Voltage Inspection
Off
12 V Battery Voltage
Results
- If It Is Abnormal, There Is A Problem With The Body Control Module.