Air Temperature Sensor
Turn ignition off. Disconnect electrical connector at airflow meter and connect ohmmeter between terminals No. 6 and 27. Readings should be as follows. If not, replace temperature sensor and airflow meter.
TEMPERATURE/RESISTANCE RELATIONSHIP
| Temperature | Ohms |
|---|---|
| 68°F (20°C) | 2,000-3,000 |
| 122°F (50°C) | 760-970 |