No Load Test
With starter on test bench, take readings of starter current, voltage and RPM. Readings should be within specifications.
STARTER NO LOAD TEST SPECIFICATIONS
| Model | Volts/Amps. | RPM |
|---|---|---|
| 208 xxx | 11.5/35-55 | 6000-8000 |
| 211 xxx | 11.5/30-50 | 6000-9000 |
| 212 xxx | 11.5/35-55 | 6000-8000 |
| 311 xxx | 11.5/30-50 | 5500-7500 |
| 312 xxx | 11/55-85 | 8500-10,500 |
| 317 xxx | N/A | N/A |
| 362 xxx | 11.5/65-95 | 6500-8500 |