Sensor Plate Clearance Adjustment
- Remove fuel distributor from airflow sensor housing. Turn distributor upside-down to access stop screw for control piston. This will adjust free play travel range of sensor plate lever.
- Turning screw clockwise will increase clearance by keeping control piston higher in fuel distributor during operation. Turning screw counterclockwise will decrease clearance by allowing control piston to extend further out of fuel distributor during operation.
- Adjusting stop screw 1/4 turn (90 degrees) will make .05" (1.3 mm) difference at sensor plate. Idle speed and CO (current reading) must be checked.