- Item Being Tested - ABS Control Unit Ground (Terminal No. 10) Place ABS tester in program switch position No. 7. When button No. 5 lights up, press button. Reading on ABS tester should be 80-300 millivolts. If correct, TEST 7 is completed.
- If reading is incorrect, turn ignition off. Use ohmmeter to check continuity between terminal No. 10 in plug for ABS control unit and ground. See Figure . If there is no continuity, repair wiring harness to restore continuity.
IDENTIFICATION
| Fig. # | Identification |
|---|---|
| 6 | ABS Control Unit Terminal ID |
| 7 | Solenoid Valve Relay Terminal ID |
| 8 | ABS Power Supply Relay (Rear) |
| 9 | ABS Power Supply Relay Contacts (Front) |
| 10 | ID of Terminal in Plug for Hydraulic Modulator |
| 11 | ID of Terminal is Socket on Hydraulic Modulator |