Oxygen Sensor
- Disconnect differential pressure regulator connector from side of regulator. Using Adapter (1315 A/1 ), connect Multimeter (US 1119 ) to differential pressure regulator and to the connector removed from the regulator.
- Set multimeter to 200Ma DC scale. Disconnect oxygen sensor connector. Start engine and let idle. Note reading on multimeter. Ground male end of oxygen sensor connector.
- Observe multimeter. Current should increase from 9Ma to 11Ma after 15 seconds. Reconnect oxygen sensor connector. Raise engine speed to approximately 3000 RPM for a few seconds.
- Let engine idle. Current should fluctuate approximately 1-3Ma in the -10Ma to +10Ma range.