| Test Step No. 1 |
| Connection Terminals |
14 & 35 |
| Test Conditions (Addition Steps) |
Ignition "ON" |
| Test Values |
About Battery Voltage |
| Test Step No. 2 |
| Connection Terminals |
17 & 35 |
| Test Conditions (Addition Steps) |
Ignition "ON" |
| Test Values |
About Battery Voltage |
| Test Step No. 3 |
| Connection Terminals |
32 & 35 |
| Test Conditions (Addition Steps) |
Ignition & A/C "ON" |
| Test Values |
About Battery Voltage |
| Test Step No. 4 |
| Connection Terminals |
33 & 35 |
| Test Conditions (Addition Steps) |
Ignition & A/C "ON" |
| Test Values |
About One Volt Below Battery Voltage |
| Test Step No. 5 |
| Connection Terminals |
19 & 35 |
| Test Conditions (Addition Steps) |
Ignition "ON" |
| Test Values |
About Battery Voltage |
| Test Step No. 6 |
| Connection Terminals |
13 & 35 |
| Test Conditions (Addition Steps) |
Insert Fuel Relay Fuse |
| Test Values |
FIL Must Light |
| Test Conditions (Addition Steps) |
Ignition "ON" |
| Test Values |
FIL Must Light |
| Test Step No. 7 |
| Connection Terminals |
4 & 5 |
| Test Conditions (Addition Steps) |
Ignition "OFF" |
| Test Values |
15-25 Ohms |
| Test Step No. 8 |
| Connection Terminals |
3 & 35 |
| Test Conditions (Addition Steps) |
Ignition "OFF" |
| Test Values |
2500 Ohms @ 68°F (20°C) |
| Test Values |
200 Ohms @ 212°F (100°C) |
| Test Step No. 9 |
| Connection Terminals |
31 & 35 |
| Test Conditions (Addition Steps) |
Throttle Closed |
| Test Values |
Open (No Continuity) |
| Test Conditions (Addition Steps) |
Throttle Wide Open |
| Test Values |
Continuity |
| Test Step No. 10 |
| Connection Terminals |
28 & 35 |
| Test Conditions (Addition Steps) |
Throttle Closed & Open |
| Test Values |
Continuity |
| Test Step No. 11 |
| Connection Terminals |
18 & 35 |
| Test Conditions (Addition Steps) |
N/A |
| Test Values |
Continuity |
| Test Step No. 12 |
| Connection Terminals |
13 & 35 |
| Test Conditions (Addition Steps) |
Insert Fuel Relay Fuse |
| Test Values |
Continuity |
| Connection Terminals |
13 & 35 |
| Test Conditions (Addition Steps) |
Ground Test Connector |
| Test Values |
Continuity |
| Test Step No. 13 |
| Connection Terminals |
14 & 16 |
| Test Conditions (Addition Steps) |
N/A |
| Test Values |
About 10 Ohms |
| Test Step No. 14 |
| Connection Terminals |
14 & 15 |
| Test Conditions (Addition Steps) |
N/A |
| Test Values |
30-60 Ohms |
| Test Step No. 15 |
| Connection Terminals |
N/A |
| Test Conditions (AS) |
Unplug Hall Effect Sensor Connector |
| Test Values |
N/A |
| Connection Terminals |
30 & 35 |
| Test Conditions (AS) |
Terminals 1 & 2 To Hall Effect Sensor |
| Test Values |
Continuity |
| Connection Terminals |
30 & 21 |
| Test Conditions (AS) |
Terminals 2 & 3 To Hall Effect Sensor |
| Test Values |
Continuity |
| Test Step No. 16 |
| Connection Terminals |
11 & 35 |
| Test Conditions (AS) |
Remove Terminal From Power Output |
| " |
Stage Of Coil. Ground Center Contact |
| Test Values |
Continuity |
| Test Step No. 17 |
| Connection Terminals |
N/A |
| Test Conditions (AS) |
Disconnect KS Harness Connector |
| Test Values |
Open (No Continuity) |
| Connection Terminals |
6 & 8 |
| Test Conditions (AS) |
Connect Terminals 1 & 2 |
| Test Values |
Continuity |
| Test Conditions (AS) |
Connect Terminals 1 & 3 |
| Test Values |
Continuity |
| Test Step No. 18 |
| Connection Terminals |
7 & 35 |
| Test Conditions (AS) |
Disconnect O2 Connector & Ground |
| Test Values |
Continuity |
| Test Step No. 19 |
| Connection Terminals |
23 & 26 |
| Test Conditions (AS) |
Sensor Plate In Rest Position |
| Test Values |
About 5000 ohms |
| Test Step No. 20 |
| Connection Terminals |
26 & 35 |
| Test Conditions (AS) |
Sensor Plate In Rest Position |
| Test Values |
About 4000 ohms |
| Test Step No. 21 |
| Connection Terminals |
34 & 35 |
| Test Conditions (AS) |
Standard Transmission |
| Test Values |
Continuity |
| Test Conditions (AS) |
Automatic Transmission In "P" Or "N" |
| Test Values |
Open (No Continuity) |
| Test Step No. 22 |
| Connection Terminals |
12 & 35 |
| Test Conditions (AS) |
Remove Fuel Pump Relay And Ground |
| " |
Terminal No. 47 Of Fuse Panel Relay |
| Test Values |
Continuity |