Using Adapter Fittings,connect Pressure Gauge (VW 1318) between line from fuel distributor to cold start valve and test port connection on lower chamber of fuel distributor. See Figure
. Test port is sealed by a threaded plug. Bridge fuel pump relay (located on fuse/relay panel) with Jumper Switch (US 4480/3). See Figure
for fuel pump relay terminal identifications.
NOTE:
Fuel pump may also be activated by jumping 12 volts to by-pass terminal on fuse/relay panel. See the appropriate WIRING DIAGRAMS
article.