Differential Pressure Regulator Electrical System
- Connect Pressure Gauge (VW 1318) as described previously in SYSTEM PRESSURE. See Figure
. Close pressure gauge valve. Disconnect differential pressure regulator harness connector.
- Using Adapter (VW 1315 A/1), connect Multimeter (US 1119) to differential pressure regulator and harness connector. See Fig 1
. Set multimeter to 200-mA DC scale. Turn ignition on.
- Multimeter should read 100 mA. Pressure gauge should read 67-80 psi (5.5-5.9 kg/cm2
). If pressure is not as specified, check differential pressure regulator wiring and connectors. If wiring and connectors are good, replace differential pressure regulator.
Courtesy of AUDI OF AMERICA, INC.