By-Pass Valve: Notes
The By-Pass valve is located in front of turbocharger. It opens over-run phase with vacuum pressure, thus relieving existing boost pressure in front of throttle valve in order to prevent load shock during acceleration/deceleration changes. If performance is down or shock loads occur during load changes, by-pass valve must be checked.