DTC 00301 - Return Flow Pump
- Fault may be caused by the following;
- Open or high resistance in power or ground circuit to return flow pump.
- Open or short in circuit between return flow pump relay and ABS control module.
- Faulty ABS return flow pump relay.
- Faulty return flow pump.
- Faulty hydraulic unit
- Check power and ground circuit to return flow pump for open and short to ground. See WIRING DIAGRAMS . Repair circuit if necessary.
- Check circuits between ABS return flow pump relay and ABS control module for open short to ground and short to power. Repair if necessary.
- To test ABS return flow pump relay, ABS return flow pump and hydraulic unit perform steps 12) and 17) of CIRCUIT TEST . Confirm operation by checking measuring value block display field 07 with VAG 1551.