Windshield Projection Head Up Display Control Module, Calibrating
Special tools and workshop equipment required
- Calibration Tool VAS6658
Conditions
-- The windshield projection control module must be calibrated during the following conditions:
- The Windshield Projection Head Up Display Control Module -J898- was replaced.
- The windshield was removed and installed.
- The DTC "no or incorrect basic setting/adaptation" is stored in the DTC memory.
Procedure
-- Move the vehicle onto a secure flat surface.
-- Set the parking brake - the vehicle must not move during the measuring.
-- Remove the upper cover, refer to Overview - Front Door Trim Panel .
-- Fold down the left and right sun visors, disengage them and move them to the side.
-- Engage the Calibration Tool VAS6658 to the center support -1 and 2- for the sun visor.
Performing calibration
Vehicle Diagnostic Tester is attached.
-- Choose operation mode Diagnosis and start the diagnosis.
-- Select the tab test plan .
-- Select select individual tests and choose the following sequence.
- Body
- Electrical Equipment
- 01 - On Board Diagnostic (OBD) capable systems
- 82 - Windshield Projection Head Up Display Control Module - J898
- 82 - windshield projection control module, function
- 82 - calibrating the head up display
The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.
-- After calibrating the windshield projection head up control module successfully, end "calibration", turn off the ignition and disconnect the diagnostic connector.