Windshield Projection Head Up Display Control Module, Calibrating

Special Tools And Workshop Equipment Required 

Conditions 

-- The windshield projection control module must be calibrated under the following conditions:

Preliminary Work 

-- Move the vehicle onto a secure flat surface.

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Fold down the left and right sun visors, disengage them and move them to the side.

GWWA90-10205Courtesy of AUDI OF AMERICA, LLC

-- Engage the :VAS721005  on the center support -1 and 2- for the sun visor.

Calibrating Procedure 

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

-- After calibrating the windshield projection control module successfully, end "calibration", turn off the ignition and disconnect the diagnostic connector.