Windshield Projection Head Up Display Control Module -J898-, CALIBRATING

Special tools and workshop equipment required 

Conditions

-- The Windshield Projection Head Up Display Control Module -J898- must be calibrated under the following conditions:

Preliminary Work

-- Move the vehicle onto a secure flat surface.

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Fold down the left and right sun visors, disengage them and move them to the side.

-- Engaging the Head-Up Display calibration board -1- on sun visor center bearing -2 and 3-.

GWWA90-10259Courtesy of AUDI OF AMERICA, LLC

Calibrating Procedure

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester.

-- After calibrating the windshield projection control module successfully, end "calibration", turn off the ignition and disconnect the diagnostic connector.