Home >> Audi >> 2023 >> S3 Premium Plus >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool (Engine DTC Tables - Transmission DTC Tables Transmission Control Module) >> St Generic Scan Tool >> Diagnosis And Testing >> Transmission DTC Tables >> Transmission Control Module --, DL382
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Transmission Control Module --, DL382

Component / System Fault Code Monitor Strategy Description Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitoring Time Length MIL Illum.
Gear Shift Module 1-3 P2832 - Shift Fork "A" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 4-6 P2841 - Shift Fork "D" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 5-7 P283C - Shift Fork "C" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 2-R P2837 - Shift Fork "B" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 1-3 P2831 - Shift Fork "A" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 4-6 P2840 - Shift Fork "D" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 5-7 P283B - Shift Fork "C" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 2-R P2836 - Shift Fork "B" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 1-3 P2832 - Shift Fork "A" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Time of oscillation > 1.1 [ms]          
Gear Shift Module 4-6 P2841 - Shift Fork "D" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Time of oscillation > 1.1 [ms]          
Gear Shift Module 5-7 P283C - Shift Fork "C" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Time of oscillation > 1.1 [ms]          
Gear Shift Module 2-R P2837 - Shift Fork "B" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Time of oscillation > 1.1 [ms]          
Speed Sensor Shaft 1 P0718 - Input/Turbine Shaft Speed Sensor "A" Circuit Intermittent Rationality check No signal > 1 [s] Ignition On [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 2 P2768 - Input/Turbine Shaft Speed Sensor "B" Circuit Intermittent Rationality check No signal > 1 [s] Ignition On [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 1 P0501 - Vehicle Speed Sensor "A" Circuit Range/Performance Rationality check Difference between measured > 150 [rpm] Input shaft speeds for shafts 1 > 100 [rpm] 2 [s] 2 DCY
and calculated output speed for     and 2     Continuous  
shaft 1 and Difference between output shaft > 150 [rpm]          
speed 1 and shaft 2              
Speed Sensor Shaft 2 P2159 - Vehicle Speed Sensor "B" Circuit Range/Performance Rationality check Difference between measured > 150 [rpm] Input shaft speeds for shafts 1 > 100 [rpm] 2 [s] 2 DCY
and calculated output speed for     and 2     Continuous  
shaft 2 and Difference between output shaft > 150 [rpm]          
speed 1 and shaft 2              
Speed Sensor Shaft 1 and P2162 - Vehicle Speed Sensor "A"/"B" Correlation Rationality check Difference between output shaft > 150 [rpm] Input shaft speeds for shafts 1 > 100 [rpm] 2 [s] 2 DCY
speeds and input speeds shafts 1     and 2     Continuous  
and 2     and Engaged gear position is not Neutral [-]    
TCM Temperature Sensor P0666 - Control Module Internal Temperature Sensor "A" Circuit Circuit continuity TCM Temperature Sensor self failed [-] Ignition On [-] 2 [s] 2 DCY
check and TCM Temperature Sensor invalid state [-] and TCM Temperature Sensor Finished [-] Continuous  
      Initialization        
TCM Temperature Sensor P0666 - Control Module Internal Temperature Sensor "A" Circuit Circuit continuity TCM Temperature Sensor at -0.03125 [°C] Ignition On [-] 2 [s] 2 DCY
            Continuous  
and Actual chip temperature < -24 [°C] and TCM Temperature Sensor Finished [-]    
      Initialization        
or Actual chip temperature > 24 [°C]          
TCM Temperature Sensor P0667 - Control Module Internal Temperature Sensor "A" Range/Performance Rationality check Difference between TCM 26 > x > -26 [°C] Ignition On [-] 2 [s] 2 DCY
Temperature Sensor and internal           Continuous  
chip temperature     and TCM Temperature Sensor Finished [-]    
      Initialization        
TCM Temperature Sensor P0667 - Control Module Internal Temperature Sensor "A" Range/Performance Rationality check Difference between actual TCM Temperature Sensor and filtered Temperature > 8 [°C] Ignition On [-] 2 [s] Continuous 2 DCY
TCM Temperature Sensor P0713 - Transmission Fluid Temperature Sensor "A" Circuit High Circuit continuity check Short circuit to high > 4.7 [V] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
TCM Temperature Sensor P0712 - Transmission Fluid Temperature Sensor "A" Circuit Low Circuit continuity check Short circuit to ground < 0.16 [V] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance Rationality check Actual ATF temperature > 170 [°C] Power supply voltage 6•••18 [V] 2 [s] 2 DCY
            Continuous  
or              
Actual ATF temperature < -50 [°C]          
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance Circuit continuity check Difference between actual ATF temperature and filtered Temperature > 15 [°C] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
ATF Pump Speed Sensor P0C2D - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Low Signal range check Sensor output voltage < 0.25 [V] Sensor supply voltage 4.5•••5.5 [V] 2 [s] Continuous 2 DCY
ATF Pump Speed Sensor P0C2E - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal High Signal range check Sensor output voltage > 4.5 [V] Sensor supply voltage 4.5•••5.5 [V] 2 [s] Continuous 2 DCY
ATF Pump Speed Sensor P0C2C - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Range/Performance Rationality check Sensor output sin2 +cos2 > 0.8 [-] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
            Continuous  
or              
Sensor output sin2 +cos2 < 1.2 [-]          
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance Rationality check Difference between ATF temperature and TCM temperature > 20 [K] Deviation between temperature measured at the transmission control module (TCM) printed circuit board (PCB) and temperature measured in automatic transmission fluid (ATF) oil after a longer term of transmission cool down. Too high [-] 0.0 [s] Once / DCY 2 DCY
Supply Voltage Monitoring P06D5 - Sensor Reference Voltage "E" Circuit Range/Performance Signal range check Internal sensor supply voltage > 5.5 [V]     [-] 2 [s] 2 DCY
        Continuous  
or          
Internal sensor supply voltage < 4.5 [V]      
(Electrical) ATF Pump P0C2A - Electric/Auxiliary Transmission Fluid Pump Motor Stalled Functional check Current ATF pump speed 300 [rpm] ATF pump governor Enabled   2 [s] 2 DCY
            Continuous  
and     and        
Set current for ATF pump control 30•••50 [A] Target ATF-engine speed 300 [rpm]    
(Electrical) ATF Pump P0B0D - Electric/Auxiliary Transmission Fluid Pump Motor Control Module Signal range check Difference between actual and commanded ATF pump speed > 500 [rpm] Calibration Not active [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump P0C28 - Electric/Auxiliary Transmission Fluid Pump Motor Current High Functional check ATF pump over current protection active [-] Ignition On [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump Driver Circuit Performance Circuit continuity check electrical failure in power amplifier Detected [-]     [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump Driver Circuit Performance Circuit continuity check Driver error Detected [-]     [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump Driver Circuit Performance Circuit continuity check Overload ATF pump Detected [-]     [-] 2 [s] Continuous 2 DCY
Solenoid for gear 1-3 P0750 - Shift Solenoid "A" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for gear 4-6 P0765 - Shift Solenoid "D" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for gear 5-7 P0760 - Shift Solenoid "C" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for gear 2-R P0755 - Shift Solenoid "B" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for clutch 1 P0745 - Pressure Control Solenoid "A" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for clutch 2 P0775 - Pressure Control Solenoid "B" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for main pressure P0795 - Pressure Control Solenoid "C" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for cooling P0770 - Shift Solenoid "E" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and Belonging common high side Active [-]    
switch        
Solenoid for overpressure P2706 - Shift Solenoid "F" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and Active [-] 2 [s] 2 DCY
deactivation of the transmission     Continuous  
solenoid driver (SDS4)        
actuators and No transmission solenoid driver Detected [-]    
(SDS4) error and        
Belonging common high side switch Active [-]    
Gear Actuator 1-3 P284D - Shift Fork "A" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time-out in gear actuator state after synchronization > 1 [s] Gear actuator 1-3 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time-out in gear actuator state after synchronization > 1 [s] Gear actuator 4-6 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time-out in gear actuator state after synchronization > 1 [s] Gear actuator 5-7 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time-out in gear actuator state after synchronization > 1 [s] Gear actuator 2-R nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time-out in gear actuator state Unlatched > 1 [s] Gear actuator 1-3 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time-out in gear actuator state Unlatched > 1 [s] Gear actuator 4-6 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time-out in gear actuator state Unlatched > 1 [s] Gear actuator 5-7 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time-out in gear actuator state Unlatched > 1 [s] Gear actuator 2-R nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time-out in gear actuator state Unlatched > 1 [s] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time-out in gear actuator state Engage > 1 [s] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time-out in gear actuator state Engage > 1 [s] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time-out in gear actuator state Engage > 1 [s] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P2845 - Shift Fork "A" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 1-3 leaves the neutral-position > 3 [mm] Gear actuator 1-3 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2848 - Shift Fork "D" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 4-6 leaves the neutral-position > 3 [mm] Gear actuator 4-6 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P2847 - Shift Fork "C" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 5-7 leaves the neutral-position > 3 [mm] Gear actuator 5-7 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P2846 - Shift Fork "B" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 2-R leaves the neutral-position > 3 [mm] Gear actuator 2-R nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P284D - Shift Fork "A" Unrequested Movement Functional check Gear actuator 1-3 leaves the engage-position > 1 [s] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Unrequested Movement Functional check Gear actuator 4-6 leaves the engage-position > 1 [s] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Unrequested Movement Functional check Gear actuator 5-7 leaves the engage-position > 1 [s] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Unrequested Movement Functional check Gear actuator 2-R leaves the engage-position > 1 [s] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P2849 - Shift Fork "A" Stuck Functional check Time-out in gear actuator state Disengage > 2 [s] Gear actuator 1-3 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P284C - Shift Fork "D" Stuck Functional check Time-out in gear actuator state Disengage > 2 [s] Gear actuator 4-6 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284B - Shift Fork "C" Stuck Functional check Time-out in gear actuator state Disengage > 2 [s] Gear actuator 5-7 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284A - Shift Fork "B" Stuck Functional check Time-out in gear actuator state Disengage > 2 [s] Gear actuator 2-R nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time-out in gear actuator state Synchronize > 2 [s] Gear actuator 1-3 nominal state is Synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time-out in gear actuator state Synchronize > 2 [s] Gear actuator 4-6 nominal state is Synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time-out in gear actuator state Synchronize > 2 [s] Gear actuator 5-7 nominal state is Synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time-out in gear actuator state Synchronize > 2 [s] Gear actuator 2-R nominal state is Synchronized [-] 2 [s] Continuous 2 DCY
Drive-Off Clutch 1 P0811 - Excessive Clutch "A" Slippage Functional check Clutch slippage was detected > 150 [rpm] Clutch state is Drive [-] 2 [s] Continuous 2 DCY
Drive-Off Clutch 2 P081E - Excessive Clutch "B" Slippage Functional check Clutch slippage was detected > 150 [rpm] Clutch state is Drive [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 1 P0716 - Input/Turbine Shaft Speed Sensor "A" Circuit Range/Performance Signal range check Input shaft speed for shaft 1 > 12000 [rpm]     [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 2 P2766 - Input/Turbine Shaft Speed Sensor "B" Circuit Range/Performance Signal range check Input shaft speed for shaft 2 > 12000 [rpm]     [-] 2 [s] Continuous 2 DCY
Solenoid for gear 1-3 P0753 - Shift Solenoid "A" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 1 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 1 and Common low side for the magnetic valve 1 and Electric current of the magnetic valve 1 or Error at the magnetic valve 1 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for gear 5-7 P0763 - Shift Solenoid "C" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 3 and Common low side for the magnetic valve 3 and Electric current of the magnetic valve 3 or Error at the magnetic valve 3 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 1 P0748 - Pressure Control Solenoid "A" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 1 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 1 and Common low side for the magnetic valve 1 and Electric current of the magnetic valve 1 or Error at the magnetic valve 1 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for overpressure reduction P2709 - Shift Solenoid "F" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 6 Ready [-] 2 [s] Continuous 2 DCY
Component / System   Monitor Strategy Description Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitoring Time Length MIL Illum.
            and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 6 and Common low side for the magnetic valve 6 and Electric current of the magnetic valve 6 or Error at the magnetic valve 6 Finished Active >= 200 Detected [-] [-] [mA] [-]    
Solenoid for gear 2-R P0758 - Shift Solenoid "B" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 2 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 2 and Common low side for the magnetic valve 2 and Electric current of the magnetic valve 2 or Error at the magnetic valve 2 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for gear 4-6 P0768 - Shift Solenoid "D" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 3 and Common low side for the magnetic valve 3 and Electric current of the magnetic valve 3 or Error at the magnetic valve 3 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 2 P0778 - Pressure Control Solenoid "B" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 2 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 2 and Common low side for the magnetic valve 2 and Ready Finished Active [-] [-] [-] 2 [s] Continuous 2 DCY
            Electric current of the magnetic valve 2 or Error at the magnetic valve 2 >= 200 Detected [mA] [-]    
Solenoid for main pressure P0798 - Pressure Control Solenoid "C" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 3 and Common low side for the magnetic valve 3 and Electric current of the magnetic valve 3 or Error at the magnetic valve 3 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for cooling P0773 - Shift Solenoid "E" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 5 and transmission solenoid driver (SDS4) test sequence for the the magnetic valve 5 and Common low side for the magnetic valve 5 and Electric current of the magnetic valve 5 or Error at the magnetic valve 5 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
TCM internal driver A P0702 - Transmission Control System Electrical Circuit continuity check Internal voltage Failure [-] transmission solenoid driver (SDS4) A monitoring and Error in the supply voltage of the transmission solenoid driver (SDS4) A and State of the transmission solenoid driver (SDS4) A switch off path Active Not detected Active [-] [-] [-] 2 [s] Continuous 2 DCY
TCM internal driver B P0702 - Transmission Control System Electrical Circuit continuity check Internal voltage Failure [-] transmission solenoid driver (SDS4) B monitoring and Error in the supply voltage of the transmission solenoid driver (SDS4) B and Active Not detected [-] [-] 2 [s] Continuous 2 DCY
State of the transmission solenoid driver (SDS4) B switch off path Active [-]    
TCM internal driver C P0702 - Transmission Control System Electrical Circuit continuity check Internal voltage Failure [-] transmission solenoid driver (SDS4) C monitoring and Error in the supply voltage of the transmission solenoid driver (SDS4) C and State of the transmission solenoid driver (SDS4) C switch off path Active Not detected Active [-] [-] [-] 2 [s] Continuous 2 DCY
TCM P0700 - Transmission Control System (MIL Request) Functional check Central processing unit (CPU) permanent shutdown of all actors Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error Rationality check Comparison of EEProm date - both copies Invalid [-] Reading operation of datablock Active [-] 2 [s] Continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error Memory check Comparison of stored value - both copies Invalid [-] Reading operation of datablock Active [-] 2 [s] Continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error Memory check Write ability check Failed [-]     [-] 2 [s] Continuous 2 DCY
TCM P0701 - Transmission Control System Range/Performance Functional check Repeated malfunctions at switch off path check (SOPC) Detected [-]       2 [s] Once / DCY 2 DCY
Supply Voltage Monitoring Stage 1 P0560 - System Voltage Signal range check Internal sensor supply voltage or Internal sensor supply voltage > 5.5 < 4.5 [V] [V]     [-] 2 [s] Continuous 2 DCY
Supply voltage Monitoring Stage 2 P0560 - System Voltage Signal range check Internal sensor supply voltage or Internal sensor supply voltage > 5.5 < 4.5 [V] [V]     [-] 2 [s] Continuous 2 DCY
TCM internal driver A P06A6 - Sensor Reference Voltage "A" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver A is Set [-] Transmission solenoid driver (SDS4) A monitoring Active [-] 2 [s] Continuous 2 DCY
TCM internal driver B P06A7 - Sensor Reference Voltage "B" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver B is Set [-] Transmission solenoid driver (SDS4) B monitoring Active [-] 2 [s] Continuous 2 DCY
TCM internal driver C P06A8 - Sensor Reference Voltage "C" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver C is Set [-] Transmission solenoid driver (SDS4) C monitoring Active [-] 2 [s] Continuous 2 DCY
Supply Voltage Monitoring P06A9 - Sensor Reference Voltage "D" Circuit Range/Performance Signal range check Internal sensor supply voltage < 9 [V]     [-] 2 [s] Continuous 2 DCY
Supply Voltage Monitoring P0562 - System Voltage Low Signal range check Supply Voltage and one of the following monitors P0750, P0765, P0760, P0755, P0745, P0775, P0795, P0770, P2706 protective function is < 8 Active [V] [-]     [-] 5 [s] Continuous 2 DCY
(Electrical) ATF Pump P0B0A - Electric/Auxiliary Transmission Fluid Pump Motor Supply Voltage Circuit Low Signal range check Supply Voltage and P0B0D protective function is < 10 Active [V] [-] Ignition On [-] 2 [s] Continuous 2 DCY
Supply Voltage Monitoring P0563 - System Voltage High Signal range check Supply Voltage > 18 [V]     [-] 2 [s] Continuous 2 DCY
FlexRay U0151 - Lost Communication With Restraints Control Module Communication check Communication with restraints control module Failed [-] Ignition On [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 1 P0747 - Pressure Control Solenoid "A" Stuck On Functional check Difference in actual pressure on clutch K1 compared to the requested pressure on clutch K1 Detected [-]     [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 2 P0777 - Pressure Control Solenoid "B" Stuck On Functional check Difference in actual pressure on clutch K2 compared to the requested pressure on clutch K2 Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM P060B - Internal Control Module A/D Processing Performance Rationality check Repeated implausible sensorsignal Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Traction in the opposite driving direction Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Selection of too low gear and clutch Detected Closed [-] [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Selection of too low gear Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM P2C83 - Cold Start Shift Time Too Short Functional check Engine minimum speed requirement, sent from Engine Control Modul (ECM) to Transmission Control Module (TCM) during cold start Not satisfied [-] No transmission malfunction that reduces the available gears and gear selection is and Detected D or S [-] [-] Once / DCY 2 DCY
            a minimum speed requirement caused by Cold Start Emission Reduction Strategy (CSERS) by Transmission Control Module (TCM) is Received [-]    
TCM P0895 - Shift Time Too Short Functional check Engine minimum speed requirement, sent from Engine Control Module (ECM) to Transmission Control Module (TCM) because of an OBD relevant measure (not Cold Start Emission Reduction Strategy (CSERS)) Not satisfied [-] No transmission malfunction that reduces the available gears and gear selection is and a minimum speed requirement caused by an OBD relevant measure (not Cold Start Emission Reduction Strategy (CSERS)) by Transmission Control Module (TCM) is Detected D or S Received [-] Multiple 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Engagement of two gears on one shaft Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Closure of both clutches Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Incorrect clutch actuation Detected [-]     [-] 2 [s] Continuous 2 DCY
Flexray U0080 - Vehicle Communication Bus F Communication check No Flexray synchronisation Detected [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM U0100 - Lost Communication With ECM/PCM "A" Communication check Engine Control Module No signal [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ABS U0121 - Lost Communication With Anti-Lock Brake System (ABS) Control Module "A" Communication check Anti-Lock Brake System No signal [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM U0401 - Invalid Data Received From ECM/PCM "A" Communication check Data received from Engine Control Module Invalid [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ABS U0415 - Invalid Data Received from Anti-Lock Brake System (ABS) Control Module "A" Communication check Data received from Anti-Lock Brake System Invalid [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM P0614 - ECM/TCM Incompatible Rationality check Information of transmission code Faulty [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM P0614 - ECM/TCM Incompatible Rationality check Information of engine code Faulty [-] Ignition On [-] 2 [s] Continuous 2 DCY
TCM U1103 - Production mode active Functional check Production mode active [-] Ignition On [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Difference between measured and Synchronized shaft speed 1 and gear actuator 1-3 movement or gear actuator 1-3 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Difference between measured and Synchronized shaft speed 2 and gear actuator 4-6 movement or gear actuator 4-6 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Difference between measured and Synchronized shaft speed 1 and gear actuator 5-7 movement or gear actuator 5-7 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY