| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Unit | Secondary Parameters | Enable Condition | Unit | Monitor Frequency of Checks | Monitoring Time Length | Unit | MIL Illum. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Hybrid CAN | U014B - Lost Communication With Hybrid/EV Battery Inductive Charging Module | Lost communication with control module for contact-less charging (time out) | Message time out | = detected | [-] | Ignition | = on | [-] | continuous | 2, 370 | [ms] | 1 DCY |
| OR | ||||||||||||
| Autonomous HV request | = commanded on | [-] | ||||||||||
| U0112 - Lost Communication With Battery Energy Control Module "B" | Lost communication with Battery Energy Control Module "B" (time out); BMS 1 | Message time out | = detected | [-] | Ignition | = on | [-] | continuous | 870 | [ms] | 1 DCY | |
| OR | ||||||||||||
| Autonomous HV request | = commanded on | [-] | ||||||||||
| Lost communication with Battery Energy Control Module "B" (time out), other BMS | Message time out | = detected | [-] | Ignition | = on | [-] | continuous | 5, 370 | [ms] | 1 DCY | ||
| OR | ||||||||||||
| Autonomous HV request | = commanded on | [-] | ||||||||||
| U0298 - Lost Communication With DC/DC Converter Control Module "A" | Lost communication with DC/DC Converter Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition | = on | [-] | continuous | 1, 645 | [ms] | 1 DCY | |
| OR | ||||||||||||
| Autonomous HV request) | = commanded on | |||||||||||
| Driving mode] | = not active | |||||||||||
| OR | ||||||||||||
| Driving mode | = active | [-] | continuous | 5, 370 | [ms] | 1 DCY | ||||||
| U0110 - Lost Communication With Drive Motor Control Module "A" | Lost communication with Drive Motor Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition | = on | [-] | continuous | 1, 645 | [ms] | 1 DCY | |
| OR | ||||||||||||
| Autonomous | = commanded on | |||||||||||
| HV request) | ||||||||||||
| Driving mode] | = not active | |||||||||||
| OR | ||||||||||||
| Driving mode | = active | [-] | continuous | 5, 370 | [ms] | 1 DCY | ||||||
| Lost communication with Drive Motor Control Module "A" (time out) | Message time out | = detected | [-] | (Ignition | = on | [-] | continuous | 5, 370 | [ms] | 1 DCY | ||
| OR | ||||||||||||
| Autonomous | = commanded on | [-] | ||||||||||
| HV request) | ||||||||||||
| Driving mode | = not active | [-] | ||||||||||
| U0292 - Lost Communication With Drive Motor Control Module "B" | Lost communication with Drive Motor Control Module "B" (time out) | Message time out | = detected | [-] | (Ignition | = on | [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| OR | ||||||||||||
| Autonomous | = commanded on | [-] | ||||||||||
| HV request) | ||||||||||||
| Driving mode | = not active | [-] | ||||||||||
| U019B - Lost Communication With Battery Charger Control Module "A" | Lost communication with Battery Charger Control Module "A" (time out) | Message time out | = detected | [-] | Ignition | = on | [-] | continuous | 1, 420 | [ms] | 1 DCY | |
| OR | ||||||||||||
| Autonomous | = commanded on | [-] | ||||||||||
| HV request | ||||||||||||
| U0116 - Lost Communication With Coolant Temperature Control Module | Lost communication with Coolant Temperature Control Module (time out); Time 07 | Message time out | = detected | [-] | Driving mode | active | [-] | continuous | 370 | [ms] | 2 DCY | |
| Lost communication with Coolant Temperature Control Module (time out); Time 01 | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5, 370 | [ms] | 2 DCY | ||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Invalid data received from control module for contact-less charging | Invalid checksum | ≥ 2 consecutive | [-] | Ignition | = on | [-] | continuous | 770 | [ms] | 1 DCY | |
| OR | OR | |||||||||||
| Message counter | ≥ 8 repetitions | [-] | Autonomous | = commanded on | [-] | continuous | 1, 970 | [ms] | ||||
| HV request | ||||||||||||
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Invalid data received from Battery Energy Control Module "B"; BMS 1 | Invalid checksum | ≥ 2 consecutive | [-] | Ignition | = on | [-] | continuous | 390 | [ms] | 1 DCY | |
| OR | OR | |||||||||||
| Message counter | ≥ 31 repetitions | [-] | Autonomous HV request | = commanded on | [-] | continuous | 680 | [ms] | ||||
| Invalid data received from Battery Energy Control Module "B"; BMS 4 | Invalid checksum | ≥ 2 consecutive | [-] | Ignition | = on | [-] | continuous | 1, 370 | [ms] | 1 DCY | ||
| OR Message counter | ≥ 5 repetitions | [-] | OR Autonomous HV request | = commanded on | [-] | continuous | 2, 870 | [ms] | ||||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Invalid data received from Drive Motor Control Module "A" | Invalid checksum | ≥ 2 consecutive | [-] | (Ignition | = on | [-] | continuous | 470 | [ms] | 1 DCY | |
| OR Message counter | ≥ 25 repetitions | [-] | OR Autonomous HV request) | = commanded on | [-] | continuous | 1, 620 | [ms] | ||||
| Driving mode | = not active | [-] | ||||||||||
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Invalid data received from DC/DC Converter Control Module "A" | Invalid checksum | ≥ 2 consecutive | [-] | (Ignition | = on | [-] | continuous | 470 | [ms] | 1 DCY | |
| OR Message counter | ≥ 25 repetitions | [-] | OR Autonomous HV request) | = commanded on | [-] | continuous | 1, 620 | [ms] | ||||
| Driving mode | = not active | [-] | ||||||||||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Invalid data signal received from Drive Motor Control Module "A" | Invalid checksum | ≥ 2 consecutive | [-] | (Ignition | = on | [-] | continuous | 1, 370 | [ms] | 1 DCY | |
| OR Message counter | ≥ 5 repetitions | [-] | OR Autonomous HV request) | = commanded on | [-] | continuous | 2, 870 | [ms] | ||||
| AND Driving mode | = not active | [-] | ||||||||||
| U0593 - Invalid Data Received From Drive Motor Control Module "B" | Invalid data received from Drive Motor Control Module "B" | Invalid checksum | ≥ 2 consecutive | [-] | (Ignition | = on | [-] | continuous | 1, 370 | [ms] | 1 DCY | |
| OR Message counter | ≥ 5 repetitions | [-] | OR Autonomous HV request) | = commanded on | [-] | continuous | 2, 870 | [ms] | ||||
| AND Driving mode | = not active | [-] | ||||||||||
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Invalid data received from Battery Charger Control Module "A" | Invalid checksum | ≥ 2 consecutive | [-] | Ignition | = on | [-] | continuous | 570 | [ms] | 1 DCY | |
| OR Message counter | ≥ 10 repetitions | [-] | OR Autonomous HV request | = commanded on | [-] | continuous | 1, 370 | [ms] | ||||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Implausible signal received from control module for contact-less charging | Wireless HV charging module error state signal | = init | [-] | (Ignition OR Autonomous HV request) | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| Driving mode | = not active | [-] | ||||||||||
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Implausible signal received from Battery Energy Control Module "B" | HV battery current state signal | = init | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| Implausible signal received from Battery Energy Control Module "B" | HV battery error state signal | = init | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | ||
| Implausible signal received from Battery Energy Control Module "B" | HV battery voltage signal | = init | [V] | Ignition OR | = on | [-] | continuous | 5, 370 | [ms] | 1 DCY | ||
| Autonomous HV request | = commanded on | [-] | ||||||||||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Implausible signal received from Drive Motor Control Module "A" | HV voltage converter HV side voltage signal | = init | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter voltage state signal | = init | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1, 620 | [ms] [ms] | 1 DCY | |
| Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = Interlock | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1, 620 | [ms] [ms] | 1 DCY | ||
| Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = none component f unction | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1, 620 | [ms] [ms] | 1 DCY | ||
| Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = defect in active discharge | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1, 620 | [ms] [ms] | 1 DCY | ||
| Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = service disconnect | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1, 620 | [ms] [ms] | 1 DCY | ||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Implausible signal received from Drive Motor Control Module "A" | Pow er electronics error state signal | = init | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Implausible signal received from Battery Charger Control Module "A" | HV charger current state signal | = init | [-] | (Ignition OR Autonomous HV request) HV charging mode Driving mode | = on = commanded on = active = not active | [-] [-] [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| Implausible signal received from Battery Charger Control Module "A" | HV charger error state signal | = init | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | ||
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = error | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| Data bus error value received from Battery Energy Control Module "B" | Information content | = no component | [-] | Ignition | = on | [-] | continuous | 920 | [ms] | 1 DCY | ||
| HV battery | function | OR Autonomous HV request | = commanded on | [-] | ||||||||
| Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = service disconnect | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 920 | [ms] | 1 DCY | ||
| Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = interlock | [-] | OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 920 | [ms] | 1 DCY | ||
| Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = invalid voltage value | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 2, 370 | [ms] | 1 DCY | ||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Information content HV converter | = invalid voltage value on HV side | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 2, 370 | [ms] | 1 DCY | |
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = error | [-] | (Ignition OR Autonomous HV request) HV charging mode Driving mode | = on = commanded on = active = not active | [-] [-] [-] [-] | continuous | 5, 370 | [ms] | 1 DCY | |
| Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = no component function | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 1, 370 | [ms] | 1 DCY | ||
| Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = interlock | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 870 | [ms] | 1 DCY | ||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Data bus error value received from control module for contact-less charging | Information content wireless HV charging | = no component function | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 2, 370 | [ms] | 1 DCY | |
| Data bus error value received from control module for contact-less charging | Information content wireless HV charging | = interlock | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 870 | [ms] | 1 DCY | ||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Information content power electronics | = interlock | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 870 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Absolute difference between the voltage measured at HV battery and the HV | > 100 | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 3, 370 | [ms] | 1 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Absolute difference between the voltage measured at HV battery and the HV | > 100 | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 3, 370 | [ms] | 1 DCY | |
| Flexray | U0100 - Lost Communication With ECM/PCM "A" | Lost communication with ECM/PCM "A" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5, 370 | [ms] | 2 DCY |
| Gateway internal control module | U0447 - Invalid Data Received From Serial Data Gateway Module "A" | Invalid data received from Gateway "A" (EEPROM error) | CASE 1: Read pattern Timer CASE 2: Read pattern Write pattern Timer | = not successful > 5 = successful = not successful > 5 | [-] [s] [-] [-] [s] | none | [-] | once / DCY | 500 | [ms] | 1 DCY | |
| Invalid data received from Gateway "A" (RAM error) | Checksum error | = detected | [-] | none | [-] | multiple | 5, 000 | [ms] | 1 DCY | |||
| Invalid data received from Gateway "A" (watchdog error) | SBC test (External reset OR Watchdog trigger) | = passed != detected != reported by the SBC | [-] [-] [-] | none | [-] | continuous | 5, 000 | [ms] | 1 DCY |