| Micro controller supply Voltage Sensor U_Terminal 30 |
P0A08 - DC/DC Converter Status Circuit |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at main micro controller and safety micro controller |
< -1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at main micro controller and safety micro controller |
> 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| 48V supply Voltage Sensor U_Terminal 40 |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range high |
Measured voltage |
> 63.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Other rationality : Plausible check with modelled value |
Differential voltage between measured and modelled value |
< -30 > 30 |
[V] [V] |
I_Terminal 30 Terminal 30_Voltage |
≥ 8 > 9 |
[A] [V] |
100 ms continuous |
2 DCY |
| Safety switch 1_1 input supply Voltage Sensor U_Safety switch1_1 |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality low : Plausible check with other sensor measurement US1_2 |
Input voltage difference between measurements at Safety switch S1_1 and Safety switch S1_2 |
< -1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_2 |
Input voltage difference between measurements at Safety switch S1_1 and Safety switch S1_2 |
> 1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Safety switch1_2 input supply Voltage Sensor U_Safety switch1_2 |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality low : Plausible check with other sensor measurement US1_3 |
Input voltage difference between measurements at Safety switch S1_2 and Safety switch S1_3 |
< -1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_3 |
Input voltage difference between measurements at Safety switch S1_2 and Safety switch S1_3 |
> 1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Safety switch1_3 input supply Voltage Sensor U_Safety switch1_3 |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality low : Plausible check with other sensor measurement US1_4 |
Input voltage difference between measurements at Safety switch S1_3 and Safety switch S1_4 |
< -1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_4 |
Input voltage difference between measurements at Safety switch S1_3 and Safety switch S1_4 |
> 1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Safety switch1_4 input supply Voltage Sensor U_Safety switch1_4 |
Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety switch S1 Functional Safety (FUSI) |
Closed Enabled |
|
100 ms continuous |
2 DCY |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality low : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at Safety switch S1_4 and Safety switch S1_1 |
< -1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at Safety switch S1_4 and Safety switch S1_1 |
> 1.0 |
[V] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| 11V actuator supply check Voltage Sensor - main uC |
P0A08 - DC/DC Converter Status Circuit |
Rationality check : Verification with limit values |
Measured voltage |
≤ 10.5 ≥ 15.0 |
[V] |
U_Terminal 30 |
> 4.5 |
[V] |
100 ms continuous |
Immediately |
| 11V actuator supply check Voltage Sensor - Safety uC |
Rationality check : Verification with limit values |
Measured voltage |
≤ 10.5 ≥ 15.0 |
[V] |
Safety controller communication U_Terminal 30 |
ON > 4.5 |
[-] [V] |
100 ms continuous |
Immediately |
| Capacitor input voltage U_PUMP_S1 |
Rationality check : Plausibility check with other sensor measurement |
Difference between measurements at capacitor and main micro controller Terminal_30 |
≤ 8.0 ≥15.0 |
[V] [V] |
U_Terminal 30 |
≤ U_Pump_S 1 (and) > 4.5 |
[V] [V] |
100 ms continuous |
Immediately |
| Short to ground |
Measured voltage |
< 1.0 |
[V] |
Safety controller communication |
Active |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured voltage |
< 3.0 |
[V] |
Safety controller communication |
Active |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured voltage |
> 32.0 |
[V] |
Safety controller communication |
Active |
|
100 ms continuous |
Immediately |
| Safety Microcontroller supply Voltage Sensor US1_safety_uC |
P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at Safety micro controller and Safety switch S1_1 |
< -1.0 |
[V] |
Safety switch S1 Safety controller communication |
Closed Active |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement US1_1 |
Input voltage difference between measurements at Safety micro controller and Safety switch S1_1 |
> 1.0 |
[V] |
Safety switch S1 Safety controller communication |
Closed Active |
|
100 ms continuous |
2 DCY |
| Temperature Sensor absolute value t1°C converted value t1 digits |
P0A08 - DC/DC Converter Status Circuit |
Other Rationality - Erratic intermittent contact check by temperature rate of change |
Calculated rate of change of measured temperature t1 with time |
> 2.0 |
[°C / s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured temperature |
< 200 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured temperature |
> 4090 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t1 and t2 |
< -400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t1 and t2 |
>400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Temperature Sensor absolute value t2°C converted value t2 digits |
P0A08 - DC/DC Converter Status Circuit |
Other Rationality - Erratic intermittent contact check using rate of change temperature |
Calculated rate of change of temperature measurement t2 with time |
> 2.0 |
[°C / s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured temperature |
< 200 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured temperature |
> 4090 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t2 and t3 |
< -400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationaility high : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t2 and t3 |
>400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Temperature Sensor absolute value t3°C converted value t3 digits |
P0A08 - DC/DC Converter Status Circuit |
Other Rationality - Erratic intermittent contact check using rate of change temperature |
Calculated rate of change of temperature measurement t3 with time |
> 2.0 |
[°C / s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured temperature |
< 200 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured temperature |
> 4090 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t3 and t4 |
< -400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t3 and t4 |
>400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Temperature Sensor absolute value t4°C converted value t4 digits |
P0A08 - DC/DC Converter Status Circuit |
Other Rationality - Erratic intermittent contact check using rate of change temperature |
Calculated rate of change of temperature measurement t4 with time |
> 2.0 |
[°C / s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured temperature |
< 200 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured temperature |
> 4090 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Rationality low : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t4 and t1 |
< -400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with other sensor measurement |
Temperature difference between measurements at sensor t4 and t1 |
>400 |
[Digit s] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| Current Sensor Phase_1 Iph.1 |
P0A08 - DC/DC Converter Status Circuit |
Short to ground |
Measured Current_Phase 1 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 1 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 1 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 1 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.2 |
Current difference between measurements at phase 1 and 2 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.2 |
Current difference between measurements at phase 1 and 2 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_2 Iph.2 |
Short to ground |
Measured Current_Phase 2 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 2 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 2 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 2 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.3 |
Current difference between measurements at phase 2 and 3 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.3 |
Current difference between measurements at |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_3 Iph.3 |
Short to ground |
Measured Current_Phase 3 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 3 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 3 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 3 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.4 |
Current difference between measurements at |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.4 |
Current difference between measurements at |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_4 Iph.4 |
Short to ground |
Measured Current_Phase 4 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 4 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 4 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 4 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.5 |
Current difference between measurements at phase 4 and 5 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.5 |
Current difference between measurements at phase 4 and 5 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_5 Iph.5 |
Short to ground |
Measured Current_Phase 5 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 5 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 5 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 5 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.6 |
Current difference between measurements at phase 5 and 6 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.6 |
Current difference between measurements at phase 5 and 6 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_6 Iph.6 |
Short to ground |
Measured Current_Phase 6 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 6 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 6 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 6 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.7 |
Current difference between measurements at phase 6 and 7 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.7 |
Current difference between measurements at phase 6 and 7 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_7 Iph.7 |
Short to ground |
Measured Current_Phase 7 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 7 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 7 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 7 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.8 |
Current difference between measurements at phase 7 and 8 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.8 |
Current difference between measurements at phase 7 and 8 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Current Sensor Phase_8 Iph.8 |
Short to ground |
Measured Current_Phase 8 |
< -44 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Short to battery |
Measured Current_Phase 8 |
> 47.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range low |
Measured Current_Phase 8 |
< -41 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Out of range high |
Measured Current_Phase 8 |
> 44.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality low : Plausible check with other sensor measurement Iph.1 |
Current difference between measurements at phase 8 and 1 |
< -2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Rationality high : Plausible check with other sensor measurement Iph.1 |
Current difference between measurements at phase 8 and 1 |
> 2.5 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| Fan Current Sensor I_fan |
P0A94 - DC/DC Converter "A" Performance |
Short to ground |
Measured Current at Fan terminal |
< 0.015 |
[A] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Short to battery |
Measured Current at Fan terminal |
> 1.1 |
[A] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Out of range low |
Measured Current at Fan terminal |
< 0.03 |
[A] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Out of range high |
Measured Current at Fan terminal |
> 1.0 |
[A] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Rationality low : Plausible check with duty cycle (x) based limit value (y) |
Measured Current at Fan terminal is evaluated with limit value |
see sheet fan compensation |
[mA] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Rationality high : Plausible check with duty cycle (x) based limit value (y) |
Measured Current at Fan terminal is evaluated with limit value |
see sheet fan compensation |
[mA] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| FAN actuator functional check |
FAN open circuit / not plugged in to circuit |
Measured current at Fan terminal |
< 0.015 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| FAN overload failure |
Measured current at Fan terminal |
> 1.2 |
[A] |
Terminal 30 |
ON |
|
100 ms continuous |
2 DCY |
| FAN Blocked condition check by comparing fan terminal current measurement with duty cycle (x) based limit value (y) |
Calculated fan speed based on current measurement is lower than limit value |
see sheet fan compensation |
[1/mi n] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| FAN Broken condition check by comparing fan terminal current measurement with duty cycle (x) based limit value (y) |
Calculated fan speed based on current measurement is higher than limit value |
see sheet fan compensation |
[1/mi n] |
Fan duty cycle |
≥ 60 |
[%] |
100 ms continuous |
2 DCY |
| Overall System Performance Check |
P0D32 - DC/DC Converter "A" Over Temperature |
Measured temperature from all 4 sensors |
Maximum temperature out of all sensor measurements |
> 85 |
[°C] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| P0A94 - DC/DC Converter "A" Performance |
Conversion efficiency out of limit |
Ratio of output power to input power is conversion efficiency. The calculated value is compared with input current (x) based high and low efficiency limit values (y). The input current x is the sum of all 8 current sensor measurements |
High limit y = +100.1082915x0 -0.005853603x1 -4.57111e-5x2 +1.18206e-7x3 +1.12654e-11x4 ymax =100 Low limit = +78.50336709x0 +0.831397432x1 -0.020975461x2 +0.000268758x3 -1.89771e-6x4 +7.37869e-9x4 -1.47418e-11x5 +1.1789e-14x6 y min =84 |
[%] |
I_Terminal 30 U_Terminal 30 DCDC output power |
≥ 8 > 9 ≥ 100 |
[A] [V] [W] |
100 ms continuous |
2 DCY |
| P0CA3 - DC/DC Converter Step Up Voltage Performance |
Terminal 40_Under voltage with shut off detected |
Measured voltage Terminal 40 |
< 17 |
[V] |
Terminal 40 Precharge |
ON Completed |
|
100 ms continuous |
2 DCY |
| P0A08 - DC/DC Converter Status Circuit |
Check if DCDC is non functional in safe state due to Functional Safety Monitor |
|
|
|
|
|
|
|
|
| U031B - Software Incompatibility With DC/DC Converter Control Module "A" |
Functional check of applicable OBD software configuration |
CAN Signal Data set variable : OBD Mode |
= US_OBD = 1 |
[-] |
Terminal 30 OBD_Config_Check |
ON Possible |
|
100 ms continuous |
2 DCY |
| Micro controller Internal Error |
P0A08 - DC/DC Converter Status Circuit |
RAM monitor |
Number of internal RAM errors |
> 10 |
[-] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| ROM monitor |
Number of internal ROM errors |
> 5 |
[-] |
Terminal 30 |
ON |
|
100 ms continuous |
Immediately |
| NVM Monitor |
Stored and calculated checksum |
NOT MATCHING |
[-] |
Initialization |
ON |
|
Only during initialization |
Immediately |
| WD monitor |
Number of consecutive WD resets |
> 5 |
[-] |
Initialization |
ON |
|
Only during initialization |
Immediately |
| CAN_RAM monitor |
Internal error detected at CAN RAM portion |
TRUE |
[-] |
Initialization |
ON |
|
Only during initialization |
Immediately |
| CAN Communication failures |
U014A - Lost Communication With Battery Energy Control Module "C" |
Time out check |
BMS_MV_01 BMS_MV_04 |
> 0.5 >5 |
s |
H_CAN_diagnostics |
Enabled |
|
100 ms continuous |
2 DCY |
| U0100 - Lost Communication With ECM/PCM "A" |
Time out check |
Motor_Code_01 Motor_07 Motor_28 |
>5 >5 >2 |
s |
H_CAN_diagnostics |
Enabled |
|
100 ms continuous |
2 DCY |
| U0146 - Lost Communication With Serial Data Gateway Module "A" |
Time out check |
MVK_01 Klemmen_Status_01 Systeminfo_01 |
0.5 1.0 5.0 |
s |
H_CAN_diagnostics |
Enabled |
|
100 ms continuous |
2 DCY |
| U014A - Lost Communication With Battery Energy Control Module "C" |
Invalid value |
BMS_MV_IstSpannung MV_On BMS_MV_IstModus BMS_MV_IstSpannung MV_On BMS_MVIstModus |
ERROR ERROR ERROR Init Init Init |
[-] |
H_CAN_diagnostics |
Enabled |
|
100 ms continuous |
2 DCY |
| U0146 - Lost Communication With Serial Data Gateway Module "A" |
Invalid value |
MVK_DCDC_Sollmodus_02 |
ERROR |
[-] |
H_CAN_diagnostics |
Enabled |
|
100 ms continuous |
2 DCY |
| Global time out check |
no received message observed |
TIME OUT |
[-] |
|
|
|
100 ms continuous |
2 DCY |
| Bus Off at HCAN |
|
ERROR |
[-] |
|
|
|
|
|
| Safety micro controller internal failure |
P0A08 - DC/DC Converter Status Circuit |
Safety Controller software version mismatch |
Communication from safety micro controller Software ID matches with stored values |
Enabled Not matching |
[-] |
Initialization |
ON |
|
Only during initialization |
Immediately |
| Safety controller not working |
Safety controller communication request |
Not answered |
[-] |
Initialization |
ON |
|
100 ms continuous |
Immediately |
| DCDC Converter control loop monitor |
Failure occurrence frequency |
Number of failure occurrences Time window |
> 5 > 10 |
[numbers] [minutes] |
Initialization |
ON |
|
100 ms continuous |
Immediately |
| Precharge function monitor |
P0A94 - DC/DC Converter "A" Performance |
Terminal 40_Precharge rationality |
Voltage difference between target and measured voltage time since precharge start as percentage of target ramp time |
> 3 > 170 |
[V] [%] of time |
Precharge and DCDC_FSM_Precharge_Boost_ Ramp_Active |
Enabled Enabled |
|
Only during precharge |
2 DCY |