LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2025 >> S4 Premium Plus >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool (CWGD) (Brake System - Gateway Module DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Gateway Module DTC Tables >> Gateway Module --, 2024 MY
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Gateway Module --, 2024 MY

Component / System DTC / DTC Description Monitor Strategy Description Malfunction Criteria Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor Frequency of Checks Monitoring Time Length Unit MIL Illum.
Hybrid CAN U014B - Lost Communication With Hybrid/EV Battery Inductive Charging Module Lost communication with control module for contact-less charging (time out) Message time out = detected [-] Ignition = on [-] continuous 2, 370 [ms] 1 DCY
        OR            
        Autonomous HV request = commanded on [-]        
U0112 - Lost Communication With Battery Energy Control Module "B" Lost communication with Battery Energy Control Module "B" (time out); BMS 1 Message time out = detected [-] Ignition = on [-] continuous 870 [ms] 1 DCY
        OR            
        Autonomous HV request = commanded on [-]        
Lost communication with Battery Energy Control Module "B" (time out), other BMS Message time out = detected [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
        OR            
        Autonomous HV request = commanded on [-]        
U0298 - Lost Communication With DC/DC Converter Control Module "A" Lost communication with DC/DC Converter Control Module "A" (time out) Message time out = detected [-] [(Ignition = on [-] continuous 1, 645 [ms] 1 DCY
        OR            
        Autonomous HV request) = commanded on          
        Driving mode] = not active          
        OR            
        Driving mode = active [-] continuous 5, 370 [ms] 1 DCY
U0110 - Lost Communication With Drive Motor Control Module "A" Lost communication with Drive Motor Control Module "A" (time out) Message time out = detected [-] [(Ignition = on [-] continuous 1, 645 [ms] 1 DCY
        OR            
        Autonomous = commanded on          
        HV request)            
        Driving mode] = not active          
        OR            
        Driving mode = active [-] continuous 5, 370 [ms] 1 DCY
Lost communication with Drive Motor Control Module "A" (time out) Message time out = detected [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
        OR            
        Autonomous = commanded on [-]        
        HV request)            
        Driving mode = not active [-]        
U0292 - Lost Communication With Drive Motor Control Module "B" Lost communication with Drive Motor Control Module "B" (time out) Message time out = detected [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
        OR            
        Autonomous = commanded on [-]        
        HV request)            
        Driving mode = not active [-]        
U019B - Lost Communication With Battery Charger Control Module "A" Lost communication with Battery Charger Control Module "A" (time out) Message time out = detected [-] Ignition = on [-] continuous 1, 420 [ms] 1 DCY
        OR            
        Autonomous = commanded on [-]        
        HV request            
U0116 - Lost Communication With Coolant Temperature Control Module Lost communication with Coolant Temperature Control Module (time out); Time 07 Message time out = detected [-] Driving mode active [-] continuous 370 [ms] 2 DCY
Lost communication with Coolant Temperature Control Module (time out); Time 01 Message time out = detected [-] Driving mode = active [-] continuous 5, 370 [ms] 2 DCY
U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module Invalid data received from control module for contact-less charging Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 770 [ms] 1 DCY
  OR     OR            
  Message counter ≥ 8 repetitions [-] Autonomous = commanded on [-] continuous 1, 970 [ms]  
        HV request            
U0413 - Invalid Data Received From Battery Energy Control Module "B" Invalid data received from Battery Energy Control Module "B"; BMS 1 Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 390 [ms] 1 DCY
  OR     OR            
  Message counter ≥ 31 repetitions [-] Autonomous HV request = commanded on [-] continuous 680 [ms]  
Invalid data received from Battery Energy Control Module "B"; BMS 4 Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 1, 370 [ms] 1 DCY
  OR Message counter ≥ 5 repetitions [-] OR Autonomous HV request = commanded on [-] continuous 2, 870 [ms]  
U0411 - Invalid Data Received From Drive Motor Control Module "A" Invalid data received from Drive Motor Control Module "A" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 470 [ms] 1 DCY
  OR Message counter ≥ 25 repetitions [-] OR Autonomous HV request) = commanded on [-] continuous 1, 620 [ms]  
        Driving mode = not active [-]        
U0599 - Invalid Data Received From DC/DC Converter Control Module "A" Invalid data received from DC/DC Converter Control Module "A" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 470 [ms] 1 DCY
  OR Message counter ≥ 25 repetitions [-] OR Autonomous HV request) = commanded on [-] continuous 1, 620 [ms]  
        Driving mode = not active [-]        
U0411 - Invalid Data Received From Drive Motor Control Module "A" Invalid data signal received from Drive Motor Control Module "A" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 1, 370 [ms] 1 DCY
  OR Message counter ≥ 5 repetitions [-] OR Autonomous HV request) = commanded on [-] continuous 2, 870 [ms]  
        AND Driving mode = not active [-]        
U0593 - Invalid Data Received From Drive Motor Control Module "B" Invalid data received from Drive Motor Control Module "B" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 1, 370 [ms] 1 DCY
  OR Message counter ≥ 5 repetitions [-] OR Autonomous HV request) = commanded on [-] continuous 2, 870 [ms]  
        AND Driving mode = not active [-]        
U049C - Invalid Data Received From Battery Charger Control Module "A" Invalid data received from Battery Charger Control Module "A" Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 570 [ms] 1 DCY
  OR Message counter ≥ 10 repetitions [-] OR Autonomous HV request = commanded on [-] continuous 1, 370 [ms]  
U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module Implausible signal received from control module for contact-less charging Wireless HV charging module error state signal = init [-] (Ignition OR Autonomous HV request) = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
        Driving mode = not active [-]        
U0413 - Invalid Data Received From Battery Energy Control Module "B" Implausible signal received from Battery Energy Control Module "B" HV battery current state signal = init [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
Implausible signal received from Battery Energy Control Module "B" HV battery error state signal = init [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
Implausible signal received from Battery Energy Control Module "B" HV battery voltage signal = init [V] Ignition OR = on [-] continuous 5, 370 [ms] 1 DCY
        Autonomous HV request = commanded on [-]        
U0411 - Invalid Data Received From Drive Motor Control Module "A" Implausible signal received from Drive Motor Control Module "A" HV voltage converter HV side voltage signal = init [V] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
U0599 - Invalid Data Received From DC/DC Converter Control Module "A" Implausible signal received from DC/DC Converter Control Module "A" DC/DC converter voltage state signal = init [-] [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous continuous 470 1, 620 [ms] [ms] 1 DCY
Implausible signal received from DC/DC Converter Control Module "A" DC/DC converter error state signal = Interlock [-] [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous continuous 470 1, 620 [ms] [ms] 1 DCY
Implausible signal received from DC/DC Converter Control Module "A" DC/DC converter error state signal = none component f unction [-] [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous continuous 470 1, 620 [ms] [ms] 1 DCY
Implausible signal received from DC/DC Converter Control Module "A" DC/DC converter error state signal = defect in active discharge [-] [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous continuous 470 1, 620 [ms] [ms] 1 DCY
Implausible signal received from DC/DC Converter Control Module "A" DC/DC converter error state signal = service disconnect [-] [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous continuous 470 1, 620 [ms] [ms] 1 DCY
U0411 - Invalid Data Received From Drive Motor Control Module "A" Implausible signal received from Drive Motor Control Module "A" Pow er electronics error state signal = init [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
U049C - Invalid Data Received From Battery Charger Control Module "A" Implausible signal received from Battery Charger Control Module "A" HV charger current state signal = init [-] (Ignition OR Autonomous HV request) HV charging mode Driving mode = on = commanded on = active = not active [-] [-] [-] [-] continuous 5, 370 [ms] 1 DCY
Implausible signal received from Battery Charger Control Module "A" HV charger error state signal = init [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous 5, 370 [ms] 1 DCY
U0413 - Invalid Data Received From Battery Energy Control Module "B" Data bus error value received from Battery Energy Control Module "B" Information content HV battery = error [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 5, 370 [ms] 1 DCY
Data bus error value received from Battery Energy Control Module "B" Information content = no component [-] Ignition = on [-] continuous 920 [ms] 1 DCY
  HV battery function   OR Autonomous HV request = commanded on [-]        
Data bus error value received from Battery Energy Control Module "B" Information content HV battery = service disconnect [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 920 [ms] 1 DCY
Data bus error value received from Battery Energy Control Module "B" Information content HV battery = interlock [-] OR Autonomous HV request = on = commanded on [-] [-] continuous 920 [ms] 1 DCY
Data bus error value received from Battery Energy Control Module "B" Information content HV battery = invalid voltage value [V] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 2, 370 [ms] 1 DCY
U0411 - Invalid Data Received From Drive Motor Control Module "A" Data bus error value received from Drive Motor Control Module "A" Information content HV converter = invalid voltage value on HV side [V] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 2, 370 [ms] 1 DCY
U049C - Invalid Data Received From Battery Charger Control Module "A" Data bus error value received from Battery Charger Control Module "A" Information content HV charger = error [-] (Ignition OR Autonomous HV request) HV charging mode Driving mode = on = commanded on = active = not active [-] [-] [-] [-] continuous 5, 370 [ms] 1 DCY
Data bus error value received from Battery Charger Control Module "A" Information content HV charger = no component function [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous 1, 370 [ms] 1 DCY
Data bus error value received from Battery Charger Control Module "A" Information content HV charger = interlock [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous 870 [ms] 1 DCY
U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module Data bus error value received from control module for contact-less charging Information content wireless HV charging = no component function [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous 2, 370 [ms] 1 DCY
Data bus error value received from control module for contact-less charging Information content wireless HV charging = interlock [-] (Ignition OR Autonomous HV request) Driving mode = on = commanded on = not active [-] [-] [-] continuous 870 [ms] 1 DCY
U0411 - Invalid Data Received From Drive Motor Control Module "A" Data bus error value received from Drive Motor Control Module "A" Information content power electronics = interlock [-] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 870 [ms] 1 DCY
U0413 - Invalid Data Received From Battery Energy Control Module "B" Data bus error value received from Battery Energy Control Module "B" Absolute difference between the voltage measured at HV battery and the HV > 100 [V] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 3, 370 [ms] 1 DCY
U0411 - Invalid Data Received From Drive Motor Control Module "A" Data bus error value received from Drive Motor Control Module "A" Absolute difference between the voltage measured at HV battery and the HV > 100 [V] Ignition OR Autonomous HV request = on = commanded on [-] [-] continuous 3, 370 [ms] 1 DCY
Flexray U0100 - Lost Communication With ECM/PCM "A" Lost communication with ECM/PCM "A" (time out) Message time out = detected [-] Driving mode = active [-] continuous 5, 370 [ms] 2 DCY
Gateway internal control module U0447 - Invalid Data Received From Serial Data Gateway Module "A" Invalid data received from Gateway "A" (EEPROM error) CASE 1: Read pattern Timer CASE 2: Read pattern Write pattern Timer = not successful > 5 = successful = not successful > 5 [-] [s] [-] [-] [s] none   [-] once / DCY 500 [ms] 1 DCY
Invalid data received from Gateway "A" (RAM error) Checksum error = detected [-] none   [-] multiple 5, 000 [ms] 1 DCY
Invalid data received from Gateway "A" (watchdog error) SBC test (External reset OR Watchdog trigger) = passed != detected != reported by the SBC [-] [-] [-] none   [-] continuous 5, 000 [ms] 1 DCY