Generators - BOSCH: Testing: Notes

CAUTION: New or rebuilt generators must be polarized when installed, before running engine. See POLARIZING GENERATOR  in this article.

Run generator as a motor for a short period. The mechanical connection between the test bench driving motor and generator must be disconnected. Connect lead from positive battery post to terminal D+ on generator. The generator must rotate in its normal direction (thus being polarized at same time).