Pick-Up Coil Resistance Check
- Disconnect electronic control module and connect ohmmeter (set to x100 scale) between terminals No. 7 and No. 31 d of harness connector. Measure pick-up coil resistance. See PICK-UP COIL RESISTANCE SPECIFICATIONS table .
- If resistance is not within specification, remove electrical connections at distributor and connect ohmmeter leads directly to pick-up coil terminals. If resistance is still not within specification, replace distributor (if pick-up coil cannot be replaced separately).
PICK-UP COIL RESISTANCE SPECIFICATIONS
| Application | Resistance (Ohms) | |
|---|---|---|
| Audi | 890-1285 | |
| BMW | 520-700 | |
| Mercedes-Benz | 450-750 | |
| Peugeot | 604 485-700 | |
| Porsche | ||
| 924 | 890-1285 | |
| 928 | 485-700 | |
| Saab | 895-1285 | |
| Volvo | ||
| 240 Series | 850-1250 | |
| 260 Series | 540-660 | |