LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> BMW >> 1982 >> 528e Automatic Trans >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> BMW MOTRONIC Emission Control System >> Testing >> Test 12: THERMO Timer
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Test 12: THERMO Timer

  1. Check that timer is properly installed and firmly seated. Check radiator for correct coolant level. Bleed cooling system.
  2. Disconnect timer and check resistance values between plug terminals "G" and "W", "G" and ground, and "W" and ground. If values are correct, trace timer circuit and repair wiring. If values are incorrect, replace timer. See Thermo Timer Resistance Specifications .
THERMO TIMER SPECIFICATIONS

Circuit Tested Ohms
G to Ground 40-70
G to W & W to Ground
  Above 60°F (15°C) Infinite
Below 60°F (15°C) Zero