Test 13: Air Temperature Sensor
- Check electrical connections on sensor. Use L-Jetronic test 4 to check Air Temperature Sensor values. If values are incorrect, remove connector from sensor and attach ohmmeter. Check resistance between terminals 22 and 6 and compare with table. See Air Temp. Sensor Resistance Specifications .
- If resistance values are correct, trace sensor circuit and repair wiring. If values are incorrect, replace air flow sensor.
AIR TEMP. SENSOR SPECIFICATIONS
| Air Temperature °F (°C) | Ohms |
|---|---|
| 66-70 (19-21) | 2280-2720 |
| 120-124 (49-51) | 760-910 |