Air Temperature Sensor
Turn ignition switch off. Disconnect electrical connector at air flow meter and connect ohmmeter between terminals 6 and 22. Readings should be as follows. If not, replace temperature sensor and air flow meter as an assembly.
TEMPERATURE/RESISTANCE RELATIONSHIP
| Temperature | Ohms |
|---|---|
| 68°F (20°C) | 2,000-3,000 |
| 122°F (50°C) | 760-970 |