No Load Test
With starter on test bench, take readings of starter current, voltage and RPM. Readings should be within specifications.
STARTER NO LOAD TEST SPECIFICATIONS
| Model |
Volts/Amps. |
RPM |
| 208 xxx |
11.5/35-55 |
6000-8000 |
| 211 xxx |
11.5/30-50 |
6000-9000 |
| 212 xxx |
11.5/35-55 |
6000-8000 |
| 311 xxx |
11.5/30-50 |
5500-7500 |
| 312 xxx |
11/55-85 |
8500-10,500 |
| 317 xxx |
N/A |
N/A |
| 362 xxx |
11.5/65-95 |
6500-8500 |
BRUSH LENGTH & SPRING TENSION SPECIFICATIONS
| Application |
In. (mm) |
Ozs. (g) |
| 208 xxx |
.52 (13) |
40-50 (1150-1350) |
| 211 xxx |
.52 (13) |
40-46 (1150-1300) |
| 212 xxx |
N/A |
N/A |
| 311 xxx |
.52 (13) |
40-46 (1150-1300) |
| 312 xxx |
.39 (10) |
29-32 (800-900) |
| 314 xxx |
.52 (13) |
40-46 (1150-1300) |
| 317 xxx |
N/A |
N/A |
| 362 xxx |
.61 (15.5) |
40-46 (1150-1300) |