Test 6: DME Control Unit
- Check electric power supply. Turn on ignition. Connections 18 and 35 of control unit have approximately 12-volts. Connections 5, 16, 17 and 19 are connected with ground.
- Pull off relay 2 and bridge terminals 87 and 30. This supplies voltage to control unit. If necessary, check activation or replace relay 2. Turn on ignition and check voltage (12-volts) on term 85 and 86.
- To be sure that the source of defect is only in the control unit, it is recommended to replace the DME unit for comparison. In addition, carry out the various L-Jetronic test with a BMW service test unit first, depending on type of complaint.