Fuel Injector Control (Injectors 1, 3 And 5)
The test terminal is 16 and ground. Bridge terminal 36 and 2 with fused jumper wire is the test condition. Fuel injectors (1, 3 and 5) should click when terminal 16 is touched to ground is the correct test value.