Fuel Injector Control (Injectors 2, 4 And 6)
The test terminal is 17 and ground. Bridge terminal 36 and 2 with fused jumper wire is the test condition. Fuel injectors (2, 4 and 6) should click when terminal 17 is touched to ground is the correct test value.