STARTER SPECIFICATIONS

Application Specification
Axial Armature Play .1-.2 mm
Brush Length 13 mm (minimum)
Testing Voltage 11.7-12.3 Volts
Rated Power
M50, M52, S52 1.7 kW
M51 2.2 kW
M60, M62 1.7 kW
M70, M73 2.2 kW
M57 2.2 kW
M67 2.6 kW
S62 1.7 kW
Current Consumption At Terminal 50 (Rated Power Of 1.4 kW)
Pull-In Winding 54.5 A
Hold-In Winding 10.5 A
Current Consumption At Terminal 50 (Rated Power Of 1.7 kW with Intermediate Transmission)
Pull-In Winding 51 A
Hold-In Winding 9.5 A
Current Consumption At Terminal 50 (Rated Power Of 1.8 kW)
Pull-In Winding 50 A
Hold-In Winding 12 A
Current Consumption At Terminal 50 (Rated Power Of 2.0 kW)
Pull-In Winding 54.5 A
Hold-In Winding 10.5 A
Current Consumption At Terminal 50 (Rated Power Of 2.2 kW)
Pull-In Winding 58 A
Hold-In Winding 13 A
Current Consumption At Terminal 50 (Rated Power Of 2.2 kW with Intermediate Transmission)
Pull-In Winding 60 A
Hold-In Winding 10 A
Current Consumption At Terminal 50 (Rated Power Of 2.6 kW with Intermediate Transmission)
Pull-In Winding 50 A
Hold-In Winding 12 A