Priority Table For Load-Circuit Peak Reduction And Shut-Down Modes

Legend:

0= Normal operation without peak reduction (KL 15 "ON")

1= Terminal R "ON", generator defect or under voltage acknowledged.

4= Corresponds to max. peak reduction.

5= Corresponds to medium peak reduction

6= Corresponds to minimum peak reduction

PRIORITY TABLE FOR LOAD-CIRCUIT PEAK REDUCTION AND SHUT-DOWN MODES

Consumer Circuit Priority Level
0 1 4 5 6
A B A B A B A B A B
Rear Window Defogger                     
Off X   X   X   X   X  
Intermittent operation X           X   X  
On X                  
Seat Heaters                     
Switched off X   X   X   X   X  
Temperature level 1 X X       X   X   X  
Temperature level 2 X X           X   X  
Temperature level 3 X                    
Maximum rated output X               X  
Half rated output X       X   X   X  
Heater Fan                     
Speed 0   X   X            
Speed 1   X       X   X   X
Speed 2   X       X   X   X
Speed 3   X           X   X
Steering Wheel Heater                     
Level 0 X   X   X   X   X  
Level 1 (clocked mode) X           X   X  
Level 2 (fast heat up) X               X  
Mirror Heater                     
Off X   X   X   X   X  
On X                  
Windshield Heater                     
Off X   X   X   X   X  
On X                  
Wet Arm Heater                     
Off X   X   X   X   X  
On X                  
Headlight Washer System                     
Off X   X   X   X   X  
On X                  
Active Seat                     
Off X   X   X   X   X  
On X               X  
Seat Ventilation                     
Off X   X   X   X   X  
On X           X   X