Injector Opening
If the injector current feed is set by the DDE, the piezo-element contracts and the coupler module is pressed back by the spring force.
The spring in the control valve closes the valve and clears the bypass. Fuel now reaches the control volume via the bypass, outlet (7) and restrictor (5) and presses the nozzle needle down. The injector is closed and injection is finished.