4.2.6. Crash entries
In the event of a collision where one or more actuators are triggered, a crash entry is stored in a non-erasable memory. After three crash entries, a non-erasable fault memory entry is stored with the instruction to replace the Crash Safety Module.
NOTE:
The three crash entries can also be stored during the course of an accident. Each crash entry is assigned a system time.
The electronic control unit remains capable of firing even after three crash entries. The crash entries cannot be erased and are used to diagnose the device. A maximum of three crash entries can be stored. The control unit must then be replaced.
The electronic control unit remains capable of firing even after three crash entries. The crash entries cannot be erased and are used to diagnose the device. A maximum of three crash entries can be stored. The control unit must then be replaced.