12 41 041 Replacing solenoid switch
Turn off ignition .
Remove starter motor .
Release nut (1).
Remove cable lug (2).
CAUTION:
Do not turn cable lug (2) while tightening down - risk of short circuit to starter motor housing.
Tightening torque, 12 41 4AZ.
Tightening torque, 12 41 4AZ.
Release screws (1).
Remove solenoid switch (1) and spring (2).
Unhook pin (3).
Installation:
Check pin (3) for wear and apply grease.