Measures During/After Activities
When carrying out any work on the high-voltage system, it is prohibited to drive externally any of the drive train components (wheels, gearbox, drive shafts, etc.).
E72 only: When the Power Electronic Box Cover is removed, the high-voltage system is not permitted to be activated. The high-voltage safety connector may only be used if the Power Electronic Box Cover is fully installed.
High-voltage cables (orange coating) and their connectors and ferrules may not be repaired. If damaged, a cable must always be replaced completely.
When working in the vicinity of high-voltage components (identified accordingly with warning stickers and orange-coloured coating), protect these components against damage.
The specified work steps in the repair instructions must be adhered to exactly.
High-voltage components and their holders must be screwed/bolted to the defined tightening torque. Tightening torques and tightening specifications must be observed.
Connecting high-voltage components to body ground is crucial to safety for reasons of equipotential bonding. For this reason, it is prohibited to operate any high-voltage components without them being correctly connected to body ground.
For a correct earthing connection, the retaining elements of high-voltage components must not be painted. Follow further painting notes.
Removed energy accumulators must be stored in a manner that protects them from misuse and damage.