Pinion Clearance Check
- Disconnect motor field coil at solenoid terminal "M", and insulate field connector. Connect negative ground lead to starter frame. Connect 12 volts to solenoid terminal "S". Momentarily touch jumper lead from solenoid terminal "M" to starter frame, shifting pinion into cranking position.
- Push pinion as far as possible away from retainer. Using a feeler gauge, ensure there is .010-.160" (.25-4.06 mm) clearance between pinion and retainer. See Fig 1.
NOTE:
Pinion clearance is not adjustable. If clearance is not within specification, disassemble and check motor.